Power Supply
Input: |
100/240VAC, 50/60 Hz. |
Avg/Max Power Consumption: |
35 / 150 watts |
Emergency Battery Back Up: |
6-8 hours |
Throughput
Typical 240 - 360 persons per hour subject to access control system
Dimensions
External Width/Depth: |
1385mm |
Entrance Width: |
860mm |
Internal Height: |
2030mm |
External Height: |
2360mm (S), 2325mm (R) |
Servicing Clearance: |
300mm |
Typical Weight Guideline: |
880 –1120kg |
Glass Thickness: |
11mm standard, up to 31mm available |
Metallic Structure: |
Steel 30/10 |
Motors
Reversible motors with permanent magnet, working power 24VDC. Provided with an encoder for
continuous control of the door position. Door are provided with electronics control of motor torque
for door safety stop in the presence of an obstacle.
In the event of a power failure (and a fully discharged emergency battery backup) the non-secure
door will be closed and locked to prevent intrusion.
Safety
Each Portal is provided with a lever, handle or crank for unlocking the portal in an emergency. One
is located inside the portal and will only open the door on the non-secure side ensuring security
is not compromised.
The portals have a special mechanical mechanism which allows the opening of the secure door (only)
in cases when a forced opening is required. Since the mechanism is situated on the secure side and
it opens only the secure door, security is not compromised.
IR safety sensors to detect the presence of an obstacle in the doors and prevent them from closing
to avoid injury. Additional optional IR safety sensors are available.
The control electronics monitor the torque required to close the door to detect for obstructions
The portal can be connected to the building fire alarm/ emergency. In the event of a fire the doors
can be set to open either the secure, non
-secure or both doors
All portals are provided with an Emergency Battery backup in the event of a power failure. The
Portal can work on the Emergency Battery for up to 6-8 hours of continuous operation. An indicator
light and message on the control panel inform the user the Emergency battery is in use.
Control Panel and Intercom
A multifunction touch sensitive Control Panel has a clear display to allow for simple understanding
of the portals operation. The panel also allows easy changes to portal settings and operation.
One push to talk service intercom is integrated on the control panel and another one on the
security portal non secure side Traffic Light.
NB: Specifications subject to change without prior notice
Download an information sheet: