Mineral oil HLP 22 or biodegradable oil plantohyd 22 S – NWG, water hazard class 1
Control Unit
PLC in control box installed in drive cabinet (standard), PLC in separate control box for wall mounting inside a building (optional),
control voltage 24 V
Supply Voltage
400 V (3Ph + N + PE), 50 Hz
Control Box
Control unit configuration STANDARD: HxWxD = 400x400x200mm, IP 66
Control unit configuration STANDARD: HxWxD = 400x400x200mm, IP 66
Control unit configuration VARIO BASIC: HxWxD = 600x400x200mm, IP 66
Control unit configuration VARIO EFO: HxWxD = 600x400x200mm, IP 66
Control unit configuration VARIO RO3: HxWxD = 800x400x300mm, IP 66
V-striped RAL 3000 flame red / RAL 9010 pure white
Optional safety skirt
Cross striped RAL 1007 daffodil yellow / RAL 9005 jet black cross striped RAL 3000 flame red / RAL 9010 pure white or other RAL colours or DB colours Scissor joints, hydraulic cylinder, blocking element and base frame: other RAL colours
Certified according to PAS68 V/7500[N3]/80/90:0.0/20.7 and
IWA 14-1 V/7200[N3C]/80/90:0.0
Accumulator incl. rechargeable batteries for 3 movements (RO3) (optional)
Emergency fast operation (EFO): approx. 1 sec (with optional accumulator)
control voltage 24 V
Control unit configuration STANDARD: HxWxD = 400x400x200mm, IP 66
Control unit configuration VARIO BASIC: HxWxD = 600x400x200mm, IP 66
Control unit configuration VARIO EFO: HxWxD = 600x400x200mm, IP 66
Control unit configuration VARIO RO3: HxWxD = 800x400x300mm, IP 66