Crash rated sliding gate on ground track with electro-mechanical drive unit, guiding portal, receiving portal and gate leaf consisting
of bottom impact beam and top gate leaf panel
Impact Load
ASTM F 2656-07
1699 kJ (15,000 lbs @ 50mph)
PAS 68:2010
1852 kJ (7.5 t @ 80m/h)
Crash test certified according to ASTMF 2656-07m50/P1 and PAS 68:2010 V/7500[N3]/80/90:0.0/4.3 (tested with 7m CWO)
Clear Width of Opening
3.0m, 4.0m, 5.0m, 6.0m and 7.0m
Blocking Height
Gate height incl. 100mm ground clearance: 2000mm, 2500mm and 3000mm
Clear Width between Posts
Clear width of opening + 200mm
Frame Width
Clear width of opening + 2308mm
Gate Infill
Bar infillmade of square hollow section SHS 30 withmax. 120mm clearance (standard), special infill on request
Ground Track
S10 to bolt onto top edge of foundation, top of rail 20mm above finished floor level
Foundation Depth
400mm (shallow foundation)
Foundation Top Edge
100mm below finished floor level
Emergency Operation during Power
Failure
Manually after disengagement ofmotor by clutch lever
Operating Speed
Normal operation: up to 0.4m/s
Emergency Fast Operation (EFO))
Up to 0.8m/s (optional, only available for Non-European countries
Drive
1.5kW, 400 V (three-phase), 50Hz
Control Unit
WE-Tronic II in control box below drive unit cover (standard), WE-Tronic II in control box for indoor wall installation (optional), control
voltage 24V
Supply Voltage
400 V (3Ph + N + PE), 50 Hz
Control Box
H x W x D: 600mm x 400mm x 200mm, IP54
Applied Standards
DIN EN 13241-1 Industrial, commercial and garage doors and gates
Product standard - Part 1 EC-Machinery Directive (2006/42/EC) EMC Directive (2004/108/EC)
Low Voltage Directive (2006/95/EC)
Weight
Approx. 4660 – 6890kg (depending on CWO and gate height)
Colour (Standard)
RAL 6005 –moss green
RAL 7016 – anthracite grey
RAL 7030 – stone grey
RAL 7035 – light grey
RAL 9010 – pure white
Colour (Optional)
All other RAL colours or DB colours
Drive Unit Cover
In RAL colour of gate (standard) All other RAL colours or DB colours
Temperature Range
Control unit: -10°C … +50°C Drive unit: -20°C … +40°C (with power reduction up to +60°C)
of bottom impact beam and top gate leaf panel
Failure
voltage 24V
Product standard - Part 1 EC-Machinery Directive (2006/42/EC) EMC Directive (2004/108/EC)
Low Voltage Directive (2006/95/EC)
RAL 7016 – anthracite grey
RAL 7030 – stone grey
RAL 7035 – light grey
RAL 9010 – pure white