Power Supply
Input: |
100/240VAC, 50/60 Hz. |
Avg/Max Power Consumption: |
35 / 150 watts |
Emergency Battery Back Up: |
2-4 hours |
Throughput
Typical 240 - 360 persons per hour subject to access control system
Dimensions
External Width/Depth: |
1381 by 1910mm |
Entrance Width: |
885mm |
Internal Height: |
2060mm |
External Height: |
2325mm (R) |
Servicing Clearance: |
300mm |
Typical Weight Guideline: |
700 – 1020kg |
Glass Thickness: |
11mm standard, up to 27mm available |
Metallic Structure: |
Steel 30/10 |
Motors
Reversible motors with permanent magnet, working power 24VDC.
Provided with an encoder for continuous control of the door position.
Door are provided with electronics control of motor torque for door
safety stop in the presence of an obstacle.
In the event of a power failure (and a fully discharged emergency
battery backup) the non-secure door will be closed and locked to
prevent intrusion.
Safety
Each Portal is provided with a lever, handle or crank for unlocking the
portal in an emergency. One is located inside the portal and will only
open the door on the non-secure side ensuring security is not
compromised.
The portals have a special mechanical mechanism which allows the
opening of the secure door (only) in cases when a forced opening is
required. Since the mechanism is situated on the secure side and it
opens only the secure door, security is not compromised.
IR safety sensors to detect the presence of an obstacle in the doors
and prevent them from closing to avoid injury. Additional optional IR
safety sensors are available.
The control electronics monitor the torque required to close the door
to detect for obstructions
The portal can be connected to the building fire alarm/ emergency. In
the event of a fire the doors can be set to open either the secure, non
-secure or both doors
All portals are provided with an Emergency Battery backup in the
event of a power failure. The Portal can work on the Emergency
Battery for up to 2-4 hours of continuous operation. An indicator light
and message on the control panel inform the user the Emergency
battery is in use.
Control Panel and Intercom
A multifunction touch sensitive Control Panel has a clear display to
allow for simple understanding of the portals operation. The panel
also allows easy changes to portal settings and operation.
One push to talk service intercom is integrated on the control panel
and another one on the security portal non secure side Traffic Light.
NB: Specifications subject to change without prior notice